Mecer 3000VA 2400W Smart UPS (ME-3000-WPTU Winner Pro 3K)
The Mecer 3000VA 2400W smart UPS (ME-3000-WPTU Winner Pro 3K) is a high-capacity uninterruptible power supply that provides protection against power interruptions, surges, and sags. Here’s a brief description of the device:
The UPS has a high capacity of 3000VA/2400W, making it suitable for use with larger electronic equipment such as servers, workstations, and high-end gaming PCs. It is designed to provide backup power during power outages and voltage regulation during voltage sags and surges.
The Mecer ME-3000-WPTU Winner Pro 3K SMART uses online double-conversion technology, which provides continuous power supply even during a complete power failure. This helps to prevent damage to connected devices and ensures that they continue to operate even during power interruptions.
The UPS features an LCD display that provides information on the status of the device, including battery level, load capacity, and input/output voltage. It also has audible alarms to alert you of any power issues.
The ME-3000-WPTU includes surge protection, which helps to protect connected devices from voltage spikes and surges. It also has automatic voltage regulation (AVR) to stabilize voltage levels and protect equipment from under voltage and overvoltage conditions.
Features
- High capacity: The UPS has a high capacity of 3000VA/2400W, making it suitable for use with larger electronic equipment such as servers, workstations, and high-end gaming PCs.
- Online double-conversion topology: The UPS uses online double-conversion technology, which provides continuous power supply even during a complete power failure.
- Surge protection: The UPS includes surge protection to safeguard connected devices from voltage spikes and surges.
- Automatic Voltage Regulation (AVR): The UPS has AVR to stabilize voltage levels and protect equipment from under voltage and overvoltage conditions.
- LCD display and audible alarms: The UPS features an LCD display that provides information on the status of the device, including battery level, load capacity, and input/output voltage. It also has audible alarms to alert you of any power issues.
- Battery backup time: The UPS has a battery backup time of up to 15 minutes at full load and up to 40 minutes at half load, depending on the power consumption of the connected devices.
- USB interface: The UPS has a USB interface that can be used for power management and monitoring.
Specifications | |
Product Code | ME-3000-WPRU |
CAPACITY | 3000 VA / 2400 W |
PHASE | Single phase with ground |
INPUT | |
Input Voltage Range | 55-150 VAC or 110-300 VAC (Based on load at 50%); 85-140VAC or 160-280VAC (Based on load at 100%) |
Nominal Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
Frequency Range | 40Hz ~70 Hz |
Power Factor | >= 0.99 @ Nominal Voltage (100% load) |
OUTPUT | |
Voltage Regulation | ± 1% |
Output Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz |
Transfer Time : AC Mode to Battery Mode | Zero |
Transfer Time : Inverter to Bypass | 4 ms (Typical) |
Transfer Time : Waveform (Batt. Mode) | Pure Sine Wave |
Current Crest Ratio | 3::1 |
Harmonic Distortion | — 3% THD (Linear Load); — 6% THD (Non-linear Load) |
Frequency Range (Synchronized Range) | 47~53 Hz or 57~63 Hz |
EFFICIENCY | |
Battery Mode | 0.88 |
AC Mode | 0.9 |
BATTERY | |
Long-run Model : Battery Type | Depending on the capacity of external batteries |
Long-run Model : Charging Current (max.) | 1A/2A/4A/6A (Adjustable) |
Long-run Model : Charging Voltage | 82.1 VDC ± 1% ,109.4 VDC ± 1% |
Long-run Model : Numbers | 6, 8 |
Standard Model : Battery Type | 12 V / 9 AH |
Standard Model : Charging Current (max.) | 1A |
Standard Model : Charging Voltage | 82.1 VDC ± 1% |
Standard Model : Numbers | 6 |
Standard Model : Typical Recharge Time | 4 hours recover to 90% capacity |
INDICATORS | |
LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
ALARM | |
Battery Mode | Sounding every 4 seconds |
Low Battery | Sounding every second |
Overload | Sounding twice every second |
Fault | Continuously sounding |
ENVIRONMENT | |
Operating Humidity | 20~90% RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 50dB @ 1 Meter |
PHYSICAL | |
Standard Model : Dimension, D x W x H (mm) | 630 x 438 x 88 [2U] |
Standard Model : Net Weight (kgs) | 29.3 |
Long-run Model : Dimension, D x W x H (mm) | 410 x 438 x 88 [2U] |
Long-run Model : Net Weight (kgs) | 14.2 |