Specification
Main Input Voltage | 400 V 3 phases |
---|---|
Other Input Voltage | 380 V 415 V |
Main Output Voltage | 400 V 3 phases |
Other Output Voltage | 380 V 415 V |
rated power in W | 54000 W |
Rated power in VA | 60000 VA |
Output connector type | Hard wire 5-wire (3P + N + E) 1 |
Battery type | Lead-acid battery |
Provided equipment | CD with software Dust filter Installation guide Network management card Start-up service User manual |
Bypass wiring configuration | 5 wire (3P + N + E) |
---|---|
Number of power module free slots | 0 |
Number of power module filled slots | 0 |
Redundant | No |
Height | 190 cm |
---|---|
Width | 70 cm |
Depth | 95 cm |
Net weight | 735 kg |
Mounting preference | No preference |
USB compatible | No |
Network frequency | 45…65 Hz |
---|---|
Number of input connectors | 1 hard wire 5-wire (3P + N + E) |
Input voltage limits | 323…437 V adjustable 380 V 340…460 V adjustable 400 V 357…477 V adjustable 415 V 340…477 V |
Maximum input current | 228 A |
Switching current capacity | 160 A |
Max short time withstand current | 16 kA |
Input harmonic distortion | Less than 5 % for full load |
Input protection type | 3-pole circuit breaker |
Inrush current | 200 A peak |
Load power factor | 0.5 leading to 0.5 lagging |
Input Power Factor at Full Load | 0.99 |
Maximum configurable power in W | 54000 W |
---|---|
Harmonic distortion | Less than 5 % |
Output frequency | 50/60 Hz +/- 5 % sync to mains 50/60 Hz +/- 1 Hz unsynchronized |
Crest factor | 3 : 1 |
Output voltage tolerance | +/- 2% static and 100% load step |
Output harmonic distortion | < 3% linear load and < 5% non-linear load |
Output overload operation | 10 minutes at 125% and 30 seconds at 150% |
Required output current protection | 160 A |
Neutral output current | 87 A |
bypass type | Built-in static bypass |
Maximum configurable power in VA | 60000 VA |
Product certifications | CE EAC |
---|---|
Standards | EN/IEC 62040-1 EN/IEC 62040-2 EN/IEC 62040-3 ISTA 2B IEC 62040-4 |
Ambient air temperature for operation | 0…40 °C |
---|---|
Relative humidity | 0…95 % |
Operating altitude | 0…3000 ft |
Ambient air temperature for storage | -15…40 °C |
Storage Relative Humidity | 0…95 % |
Storage altitude | 0.00…4572.00 m |
Acoustic level | 65 dBA |
IP degree of protection | IP20 |
Efficiency | View Efficiency Graph |
---|---|
Number of battery filled slots | 0 |
Number of battery free slots | 0 |
Additional information | KW/kVA = 0.9 PF with ambient temp up to 25°C. kW/kVA = 0.8 PF with ambient temp above 25°C |
Battery voltage | +/- 192 V (split battery referenced to neutral) |
Discharge battery voltage | +/- 154 V |
Battery power in VAH | 0 VAh runtime |
Battery life | 3…5 year(s) |
Extended runtime | 0 |
Preinstalled device | Network management card |
---|---|
control panel | Multifunction LCD status and control console |
Emergency power off | Yes |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 197.8 cm |
Package 1 Width | 112 cm |
Package 1 Length | 82.4 cm |
Package 1 Weight | 755 kg |
ALSO CHECK
APC GALAXY G55TUPSM80HS 300 80kVA 400V
APC EASY UPS E3SUPS15KHB2 3S 15KVA 400V
APC SMART UPS G55TUPSM100HS 5500 100KVA GALAXY PARALLEL
APC SMART UPS G55TUPSM120HS 5500 120KVA GALAXY
APC GALAXY G3HT80KHB2S 300 80KVA 20MIN
Reviews
There are no reviews yet.